ELECTRICIAN IN ENGLISH Quiz - 818


In case of a flat compounded generator
  
    speed varies in proportion to the load on the generator
    voltage remains constant irrespective of the load
    voltage generated is less than the rated voltage
    generated voltage is proportional to the load on the generator

voltage remains constant irrespective of the load

Armature reaction in a generator results in
  
    demagnetization of leading pole tip and magnetization of trailing pole tip
    demagnetization of trailing pole tip and magnetization of leading pole tip
    demagnetizing the center of all poles
    magnetizing the center of all poles

demagnetization of leading pole tip and magnetization of trailing pole tip

Wave winding is composed of
  
    that even number which is exact multiple of poles
    any odd number of conductors
    any even number of conductors
    that even number which is exact multiple of poles + 2

that even number which is exact multiple of poles + 2

D.C. series generator is used
  

    to supply traction load
    to supply industrial load at constant voltage
    voltage at the toad end of the feeder
    for none of the above purpose

voltage at the toad end of the feeder

The critical resistance of the D.C. generator is the resistance of
  
    field
    load
    armature
    brushes

field

When two D.C. series generators are running in parallel an equalizer bar is used
  
    so that two similar machines will pass approximately equal currents to the load
    to increase the series flux
    to increase the speed and hence generated e.m.f.
    to reduce the combined effect of ar-mature reaction of both machines

so that two similar machines will pass approximately equal currents to the load

Following D.C. generator will be in a position to build up without any residual magnetism in the poles
  
    compound generator
    self-excited generator
    series generator
    shunt generator

self-excited generator

Which of the following generating machine will offer constant voltage on all loads ?
  
    Level compounded generator .
    Self-excited generator
    Separately excited generator
    All of the above

Level compounded generator .

Which of the following generators will be preferred if they are required to be run in parallel ?
  
    None of the above
    Compound generators
    Series generators
    Shunt generators

Shunt generators

Interpole flux should be sufficient to
  
    neutralise the commutating self induced e.m.f.
    neutralise the armature reaction flux
    neutralise both the armature reaction flux as well as commutating e.m.f. induced in the coil
    perform none of the above functions

neutralise both the armature reaction flux as well as commutating e.m.f. induced in the coil


पोस्ट अच्छी लगी हो तो प्लीज नीचे दिए गए लिंक पर क्लिक कर शेयर जरुर करें 

Post a Comment

0 Comments