The number of slip rings on a squirrel cage induction motor is usually
    none
    three
    two
    four
none
Star-delta starting of motors is not possible in case of
    high speed motors
    single phase motors
    variable speed motors
    low horse power motors
single phase motors
The term ‘cogging’ is associated with
    induction motors
    three phase transformers
    compound generators
    D.C. series motors
induction motors
The starting torque of a squirrel-cage induction motor is
    slightly more than full-load torque
    same as full-load torque
    negligible
    low
low
An induction motor with 1000 r.p.m. speed will have
    8 poles
    4 poles
    6 poles
    2 poles
6 poles
An induction motor is identical to
    asynchronous motor
    synchronous motor
    D.C. series motor
    D.C. compound motor
asynchronous motor
The torque developed in the cage induction motor with auto start is
    K2 x torque with direct switching
    K x torque with direct switching
    k/torque with direct switching
    k2/torque with direct switching
K2 x torque with direct switching
Rotor rheostat control method of speed control is used for
    none of the above
    slip ring induction motors only
    squirrel-cage induction motors only
    both and (2)
slip ring induction motors only
It is advisable to avoid line-starting of induction motor and use starter because
    motor takes five to seven times its full load current
    it will pick-up very high speed and may go out of step
    it will run in reverse direction
    starting torque is very high
motor takes five to seven times its full load current
The ‘crawling” in an induction motor is caused by
    improper design of machine
    low voltage supply
    high loads
    harmonics developed in the motor
harmonics developed in the motor